Well this was very scary, since I am wokring with production system which has 300GB DB data and backups in the SAN partitions. Problem is I don't have another SAN for my backups. So I use tape disk as alternative (now you know why i am so scared). Tape backup must be taken prior to the maintenance window (its take time). You must have good preparation plan.
I need to configure my SAN switches, so one switch failure it will route from the other switch.
First I download the HP Device Mapper Multipath Enablement Kit for HP StorageWorks Disk from HP site. And thoroughly go through the DM_Multipath document.Depending on your system architecture you must have good traffic routing plan during configuration and testing.My SAN is HP 1500MSA and OS is RHEL AS release 4 (Nahant Update 7)
Let’s begin,
1. Ensure the following RPMs bundled with the operating system distributions are installed on the system: For RHEL 4 Update 7: device-mapper-1.02.25-2.el4 or later, device-mapper-multipath-0.4.5-31.el4 or laterI had situation where, when I checked for installed rpms device-mapper-1.02.25 was installed twice (I don't know how it happened, I think this due to last OS upgrade).
# rpm -qa dev*
device-mapper-1.02.25
device-mapper-1.02.25
.....
So what I did is I upgrade the rpm to device-mapper-1.02.28-2
#rpm -Uvh device-mapper-1.02.28-2.el4.x86_64.rpm
Then I remove the rpm which didn't upgraded.
#rpm -e device-mapper-1.02.25
Then install the device-mapper-multipath-0.4.5-35.el4.x86_64.rpm also.
Finally installed rpms looks like this
# rpm -qa dev*device-mapper-multipath-0.4.5-35.el4device-mapper-1.02.28-2.el4
2. umount all SAN partitions from the host
# umount /usr/local/mysql/data -- which is our mysql data directory
3. Download HP Device Mapper Multipath Enablement Kit for HP StorageWorks Disk, which comes with template configuration file.
4. Just extract the compressed file
# cd /tmp/HPDMmultipath # tar -xvzf HPDMmultipath-4.4.1.tar.gz
# cd HPDMmultipath-4.4.1
Install the multipath setup using following command as root
# ./INSTALL
Copy template multipath configuration file to /etc/.
# cd conf
# cp multipath.conf.HPTemplate.RHEL4 /etc/multipath.conf
Restart multipath services
# /etc/init.d/multipathd restart
Create multipath devices by executing the following command:
# multipath -v0
5. My multipath.conf looks like this
# The defaults section
--------------
defaults {
udev_dir /dev
polling_interval 10
selector "round-robin 0"
path_grouping_policy failover
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
prio_callout "/bin/true"
path_checker tur
rr_min_io 100
rr_weight uniform
failback immediate
no_path_retry 12
user_friendly_names yes
bindings_file "/var/lib/multipath/bindings"
}
# For MSA A/A arrays
device {
vendor "HP"
product "MSA VOLUME*"
path_grouping_policy group_by_prio
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_checker tur
path_selector "round-robin 0"
prio_callout "/sbin/mpath_prio_alua /dev/%n"
rr_weight uniform
failback immediate
hardware_handler "0"
no_path_retry 18
rr_min_io 100
}
--------------
6. Configuring QLogic HBA ParametersEdit the /etc/modprobe.conf file with the following values (most of the configurations already there) as root
# options qla2xxx ql2xmaxqdepth=16 qlport_down_retry=10 ql2xloginretrycount=30 ql2xfailover=0 ql2xlbType=1 ql2xautorestore=0xa0 ConfigRequired=0
Rebuild the initrd by executing the following script as root
# /opt/hp/src/hp_qla2x00src/make_initrd
Reboot the host as root
# reboot
After the restart my scsi attached devices looks like this
--------------
Attached devices:
Host: scsi0 Channel: 00 Id: 00 Lun: 00
Vendor: HP Model: MSA CONTROLLER Rev: 7.00
Type: RAID ANSI SCSI revision: 04
Host: scsi0 Channel: 00 Id: 00 Lun: 01
Vendor: HP Model: MSA VOLUME Rev: 7.00
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi0 Channel: 00 Id: 00 Lun: 02
Vendor: HP Model: MSA VOLUME Rev: 7.00
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi0 Channel: 00 Id: 00 Lun: 03
Vendor: HP Model: MSA VOLUME Rev: 7.00
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi1 Channel: 00 Id: 00 Lun: 00
Vendor: HP Model: MSA CONTROLLER Rev: 7.00
Type: RAID ANSI SCSI revision: 04
Host: scsi1 Channel: 00 Id: 00 Lun: 01
Vendor: HP Model: MSA VOLUME Rev: 7.00
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi1 Channel: 00 Id: 00 Lun: 02
Vendor: HP Model: MSA VOLUME Rev: 7.00
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi1 Channel: 00 Id: 00 Lun: 03
Vendor: HP Model: MSA VOLUME Rev: 7.00
Type: Direct-Access ANSI SCSI revision: 04
--------------
So its done.
Check as much as you can from command line and system logs in order have less impact on SAN partitions.
So its done.
Check as much as you can from command line and system logs in order have less impact on SAN partitions.
# /sbin/scsi_id -g -u -s
# less /var/log/messages
I have mount my backup partition (here I didn't mount mysql data directory, which was in different partition) and did some fail-over test with SAN switches.
And its successful.
And its successful.